403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Local Reviews
for college park, md

Rated 5.0 out of 5 stars based on 4 customer reviews

Great service again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service!

M*** from Haas electric showed up on time and did a great job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Service

Michael was an amazing technician today. Knowledgeable, friendly, easy to work with. Highly recommend the company and him!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Circuit box installation

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for college park, md

dennis@haasandsons.com

dennis@haasandsons.com Job Checkin

The reason for today’s visit was to problem shoot the overhead light in the foyer after all the lights went out simultaneously. Upon arrival we visually examined the light and noticed no signs of deterioration on the outside. We moved downstairs to the panel which also showed no signs of deterioration. We then began our physical assessment on the switch connected to the light and noticed original rag wire but the rag wire and switch were both operating normally. We then disassembled the light fixture and we discovered the ballast had gone bad due to overheating resulting in the customer needing a replacement. We then presented the customer with three quotes. The first is an upgrade to a more expensive light fixture installation. The second was a replacement with a basic 6 inch light. The final quote is for the installation of a light fixture that she would provide herself. At this time she wishes not to move forward. However, if she finds a fixture she likes she will proceed to move fo


Genny G.

Genny G. Job Checkin

Customer would like new dedicated circuit for stove being converted to electric. While doing assessment, I saw panel was located in kitchen behind refrigerator. It is also very old. See below for work performed: Relocate and replace old panel with new Square D QO panel Run 40 amp dedicated circuit (using #6 AWG) for new electric range


dennis@haasandsons.com

dennis@haasandsons.com Job Checkin

Installation of new dedicated EV charger circuit mounted on the exterior of home. Installation would require circuit to be ran in SEU to the hardwired unit that customer supplied. Customer is looking to have a Level 2 Charger installed. Recommend installing water/gas bond to bring home up to date on all metallic systems being bonded together.


Genny G.

Genny G. Job Checkin

Customer would like new dedicated circuit for stove being converted to electric. While doing assessment, I saw panel was located in kitchen behind refrigerator. It is also very old. Please see solutions to get your electrical needs taken care of for you.


dennis@haasandsons.com

dennis@haasandsons.com Job Checkin

The reason for today’s visit with the customer was an estimate on a dedicated circuit for a Level 2 EV charger. After introducing to the customer i was then shown the panel location which was in the basement. The panel was a 200 amp CH panel that was recently installed on 9/2023. The panel was correctly installed with no hazards shown and also had whole home surge protection along with proper grounding and service cable/service head. The customer showed me the location she preferred for the installation which would be in the front of the home near the parking pad. The basement was unfinished with minimal drilling needed to run the SEU service cable for the hardwired EV charger. I explained my route of how i would run the cable as well as how the cable would be mounted on the exterior of the home. As i was in the basement i did see that the customer did not have all metallic systems bonded, so i recommended that we also did that while there for the car charger install. At this time cust


Matt M.

Matt M. Job Checkin

We replaced all receptacles located in the kitchen. We replaced all switches located in the kitchen. We installed a new dedicated circuit with receptacle for the refrigerator.


Matt M.

Matt M. Job Checkin

Swap motor for broken attic fan and install service switch for attic fan.


Michael W.

Michael W. Job Checkin

This estimate includes the installation of a new 150A, 30 space panel and updates to the grounding and bonding system. Original call was to inspect panel, possible phase loss. Once on site we discovered the top 2 pole breakers were found with damage along where connections were made to buss bar on A-phase. We recommend that the challenger panel be replaced with a new 150A panel. We shall return Monday morning to replace the panel and update the grounding. Permit shall be pulled for return visit. We have updated the homes grounding and bonding system and have replaced the the existing damaged panel with a new 150 panel. Inspection shall be scheduled for the 25th of July


Michael W.

Michael W. Job Checkin

This estimate includes the installation of a switch to operate the existing garbage disposal. We have installed a new switch to operate the garbage disposal.


Michael W.

Michael W. Job Checkin

This estimate includes the repair of the fault in the switching as well as the installation of the new customer supplied fixture. This estimate includes the installation of a new customer supplied chandelier in the dining room. We have repaired the switch and have installed a new customer supplied fixture in the master bathroom. In addition we have installed a new customer supplied ceiling fixture in the dining room.


Michael W.

Michael W. Job Checkin

This estimate includes the installation of a new dedicated 240V 50A dedicated circuit. We shall install customer supplied car charger and provide gfci protection to adhere to NEC standards. We have collected deposit and shall return next Wednesday to complete installation. This estimate includes the relocation of the existing dryer receptacle. We have installed customer supplied EV charger, 240V 50A dedicated circuit terminating into a exterior receptacle. In addition we have relocated the dryer circuit.


Larry B.

Larry B. Job Checkin

Installed 8 recess wafers in living room on 2 seperate Casetta dimmers with pico remotes as 3 way dimmers. Ceiling and walls were plaster so some damage occurred when cutting the holes and customer was aware of the possibility of damage with plaster. Also relocated a baseboard heater line voltage thermostat to the room in the basement where the heater is. Old location was in a seperate room so it did not turn on heater. Also installed a circuit for a hot tub out of garage sub panel with a home line spa pack gfci breaker. Swapped out breaker for garage sub panel to a 60 amp BR breaker to give more amperage for extra stuff besides hot tub. Returned 12-20-21 and hooked up power to hot tub. It is shut off at disconnect due to tub not being full yet.


Larry B.

Larry B. Job Checkin

Customer just purchased home and had some electrical issues. Replaced switches that were faulty. 3 at front door, one in hall next to basement steps, 5 at back door and 2 in hall bath on top floor. Post light needs a new head and photo cell. Front door sconces need to be replaced. Microwave has a internal issue that will require a appliance repair company. Panel is water damaged and was done without a permit or inspection. Strongly recommend replacing. Larry 240-575-0063


Michael W.

Michael W. Job Checkin

This estimate includes the installation of 2 new dedicated 120V 20A circuits. One for each of the upstairs bedrooms to provide power for space heater equipment. Each dedicated circuit shall be ARC-fault protected from the main panel. We have installed 2 dedicated 120V 20A circuits in the second floor of home for use of space heaters. Breakers labeled in panel.


Nicholas T.

Nicholas T. Job Checkin

Installed new customer supplied fan in 1st floor bathroom and ran 4” venting to a new gooseneck rooftop vent out that we installed today. We sealed new vent out down with roofing tar and slid flashing underneath shingles to avoid water leaking into the attic. We installed new brace box in bathroom and mounted customer supplied vanity light. We replaced burnt out GFCI outlet in the kitchen next to the fridge.